Energy-optimized compressed air supply in welding powder production
The Wolff engineering firm was tasked with significantly optimizing the energy efficiency of a customer's compressed air supply. The base-to-peak load ratio of 1:10, constant pressure for the conveying systems, and utilization of waste heat for heating all had to be maintained. To achieve this, existing compressors were converted to speed control via Profinet frequency converters, air flow measurement for consumption recording was integrated via Modbus RTU, and three compressors each […]
Replacing existing panels with remote visualizations
Am Anfang war nur die alte aber verlässliche Maschine mit der Siemens-S7-300er und dem sich langsam auflösendem Display, was keiner mehr bedienen konnte (und wollte.) „Mach mal neu aber verursache keine Kosten!“ So oder ähnlich war die Ansage des technischen Leiters an den jungen Techniker Julian Werner bei einem mittelständischen Automobilzulieferer. Die Lösung war wie […]
Saving energy with INSEVIS S7 controllers
Energieeinsparungen sind nötig und deshalb überall an der Tagesordnung. Wie einfach es mit den INSEVIS-S7-Panel-SPSen geht, zeigt sich an einem Projekt, welches durch das IB Wolff bei bei Oerlikon Schweißtechnik ausgeführt wurde. Hier galt es, die Kompressoren via Profinet per FU auf Drehzahlregelung umzubauen und diese über per Modbus-RTU verbundene Luftmengenmessung und Verbrauchserfassung sowie einer […]
Retrofit with INSEVIS-S7 CPUs underground
With these robust roadheaders, tunnels can be widened quite easily. Wikipedia says that in the 1960s, these were modified tank chassis to which a boom with cutter heads was mounted. The basic principle hasn't changed. The load underground is high, creating dust and shaking throughout the entire shift. But the machines are built to last [...]
INSEVIS helps S7 users with fast delivery
Here is a quote from a satisfied new INSEVIS customer: „In July 2022, ZECH Water Technology GmbH built a hydraulic groundwater remediation plant for a client in Hamburg. The operation of this plant is, among other things, a prerequisite for the commencement and further execution of construction work at the site. Contaminated groundwater is to be pumped from a deep well pump through nozzles into a […]
Digital admission control with INSEVIS S7 remote visualization
Corona hat unsere Art, mit Pandemien zu leben nachhaltig beeinflusst. Oft haben wir erstaunt nach Asien geblickt und uns über die schnelle Nachverfolgbarkeit der Infektionswege gewundert. Offensichtlich wurden die nötigen Prozesse dort eher digitalisiert als hierzulande. Die naheliegende Lösung war die digitale Überwachung der behördlich geregelten Personenanzahlen pro Fläche. Hier wurde mit der kleinsten S7-Panel-SPS […]
S7 PLCs from INSEVIS qualified as alternative
Als im Jahr 2022 die Halbleiterkrise große Konzerne zwang, Ihren Kunden die Liefertermine sukzessive auf den Sankt-Nimmerleinstag zu verschieben, wurde vielen Anwendern schlagartig klar, welchen Risiken sie sich durch fehlende Ersatzlieferanten ausgesetzt hatten. Man konnte abwarten und hoffen, dass alles gut wird. Oder man konnte handeln, so wie die Firma http://www.bueter.de/ in Meppen. Man suchte […]